Lot WB Template

Warning

This node is currently under testing

The Lot Water Balance Template node defines the “plumbing” on a lot and it connects to the sub catchment network (see Table 2 for the list of connections). For example, a typical configuration combines grey and black water to sewerage, and potable, non potable and outdoor demand to potable demand ( see Table 3 for the default configuration). With the exception of green roofs, lot scale storage and treatment systems are assigned on the basis lot templates (see nodes/lot_catchment_scale_storage). To test scenarios with a limited uptake of storage solution the Fraction of lots to assign template ID can be used. If set to < 1 it will only assign a faction of randomly selected nodes to the new template.

Note

To be able to connect flows at sub catchment level ensure that the lot scale flow is routed correctly. Otherwise the flow will be 0 Eg. for a purple pipe, non-potable and outdoor demand should be combined to non potable demand.

Table 2 Lot Scale and Sub Catchment Scale Flows

Lot Scale

Sub Catchment Scale

potable demand

potable demand

non potable demand

non potable demand

outdoor demand

outdoor demand

black water

sewerage

grey water

grey water

roof runoff

stormwater runoff

impervious runoff

evapotranspiration

pervious runoff

infiltration

evapotranspiration

impervious runoff

infiltration

Table 3 Lot Scale to Sub Catchment Scale defaults

Lot Scale

Sub Catchment Scale

potable demand

potable demand

non potable demand

potable demand

outdoor demand

potable demand

black water

sewerage

grey water

sewerage

roof runoff

stormwater runoff

impervious runoff

stormwater runoff

pervious runoff

stormwater runoff

evapotranspiration

evapotranspiration

infiltration

infiltration

Parameter

Name

Type

Description

Default

Values

fraction of nodes to assigment template ID

DOUBLE

fraction

0.1

0-1

potable demand

INT

sub catchment stream

potable demand

1-8

non potable demand

INT

sub catchment stream

potable demand

1-8

outdoor demand

INT

sub catchment stream

potable demand

1-8

black water

INT

sub catchment stream

sewerage

1-8

grey water

INT

sub catchment stream

sewerage

1-8

roof runoff

INT

sub catchment stream

stormwater runoff

1-8

impervious runoff

INT

sub catchment stream

stormwater runoff

1-8

pervious runoff

INT

sub catchment stream

stormwater runoff

1-8

evapotranspiration

INT

sub catchment stream

evapotranspiration

1-8

infiltration

INT

sub catchment stream

infiltration

1-8