Lot WB Template¶
Warning
This node is currently under testing
The Lot Water Balance Template node defines the “plumbing” on a lot and it connects to the sub catchment network (see Table 2 for the list of connections). For example, a typical configuration combines grey and black water to sewerage, and potable, non potable and outdoor demand to potable demand ( see Table 3 for the default configuration). With the exception of green roofs, lot scale storage and treatment systems are assigned on the basis lot templates (see nodes/lot_catchment_scale_storage). To test scenarios with a limited uptake of storage solution the Fraction of lots to assign template ID can be used. If set to < 1 it will only assign a faction of randomly selected nodes to the new template.
Note
To be able to connect flows at sub catchment level ensure that the lot scale flow is routed correctly. Otherwise the flow will be 0 Eg. for a purple pipe, non-potable and outdoor demand should be combined to non potable demand.
Lot Scale |
Sub Catchment Scale |
---|---|
potable demand |
potable demand |
non potable demand |
non potable demand |
outdoor demand |
outdoor demand |
black water |
sewerage |
grey water |
grey water |
roof runoff |
stormwater runoff |
impervious runoff |
evapotranspiration |
pervious runoff |
infiltration |
evapotranspiration |
|
impervious runoff |
|
infiltration |
Lot Scale |
Sub Catchment Scale |
---|---|
potable demand |
potable demand |
non potable demand |
potable demand |
outdoor demand |
potable demand |
black water |
sewerage |
grey water |
sewerage |
roof runoff |
stormwater runoff |
impervious runoff |
stormwater runoff |
pervious runoff |
stormwater runoff |
evapotranspiration |
evapotranspiration |
infiltration |
infiltration |
Parameter¶
Name |
Type |
Description |
Default |
Values |
---|---|---|---|---|
fraction of nodes to assigment template ID |
DOUBLE |
fraction |
0.1 |
0-1 |
potable demand |
INT |
sub catchment stream |
potable demand |
1-8 |
non potable demand |
INT |
sub catchment stream |
potable demand |
1-8 |
outdoor demand |
INT |
sub catchment stream |
potable demand |
1-8 |
black water |
INT |
sub catchment stream |
sewerage |
1-8 |
grey water |
INT |
sub catchment stream |
sewerage |
1-8 |
roof runoff |
INT |
sub catchment stream |
stormwater runoff |
1-8 |
impervious runoff |
INT |
sub catchment stream |
stormwater runoff |
1-8 |
pervious runoff |
INT |
sub catchment stream |
stormwater runoff |
1-8 |
evapotranspiration |
INT |
sub catchment stream |
evapotranspiration |
1-8 |
infiltration |
INT |
sub catchment stream |
infiltration |
1-8 |